iBoot can be set for operating voltages of 105-125 VAC or 210-
240 VAC by setting the voltage selector switch located on the
side of the unit to the appropriate position 115 or 230. Make
sure the switch is set to the correct position before applying
power.
Connect the device to be powered ON and OFF to the IEC
receptacle marked Switched Outlet. A short IEC 320 to North
American (NEMA 5-15) power cord is included for connecting the
iBoot outlet to the device to be power controlled. The iBoot can
be connected to a power strip to allow simultaneous control of
multiple devices.
Make sure that the combined load of all controlled devices does
not exceed 12 Amps for 115VAC or 10 Amps for 230VAC.
Connect the supplied power cord to the connector labeled AC
Input, and the other end to your AC source. If a power cord
with a different terminating plug is required, be sure it is properly
rated and meets all the required local electrical standards.
An LED Indicator next to the Switched Outlet will be On to
indicate that the power is On at that outlet. This LED will turn Off
to indicate that the power to the switched outlet is Off.