Dux Prodigy 5 135DB5P 소유자 매뉴얼 - 페이지 4

{카테고리_이름} Dux Prodigy 5 135DB5P에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dux Prodigy 5 135DB5P 20 페이지. 5 star gas hot water heater

Dux Prodigy 5 135DB5P 소유자 매뉴얼
Clearances:
Clause 6.9 of AS/NZS 5601.1 specifies
the minimum clearances required
between the water heater and building
features, structures and other items.
As a guide, some of the common
clearance requirements are set out
below:
At least 300 mm below any eaves,
balconies or other projections.
Note at least half the height of the
water heater is recommended as
clearance to provide access to the
anode.
At least 500 mm from any external
corner.
ELECTRICITY METER
OR FUSE BOX
500mm MIN
2
Owner's Manual – Prodigy 5
Installation Requirements
500mm MIN
At least 500 mm from any return
wall or other structure facing the
side of the water heater.
At least 1000 mm from any gas
meter.
At least 500 mm from any electricity
meter or fuse box.
At least 500 mm from any openable
window or door.
For a full list of the requirements and
exemptions please refer to
AS/NZS 5601.1.
GAS METER
300mm MIN
1000mm MIN
500mm MIN
500mm MIN
WINDOW OR
OTHER OPENING
DOOR
500mm MIN
H3109
3109
Rev. J