Maintenance
Fluid Packing Replacement

Removal

1. Ensure the spray gun is depressurized.
2. Remove the air cap retaining ring air cap.
3. Remove the fluid tip using the DUX 10mm fluid
tip driver.
4. Unscrew the trigger housing and fully remove it,
along with the fluid needle and trigger piston
from the main spray gun body (See Figure 14).
CAUTION: The needle spring is under
pressure and is retained by this cap. It may
spring free when the cap is removed.
5. Using a flat-blade screwdriver, remove the
packing
adjustment
counter-clockwise (See Figure 15).
6. Insert the DUX fluid packing tool into the
stainless steel fluid barrel at the front of the
spray gun.
7. Remove the fluid packing components by
pushing the DUX fluid packing tool fully toward
the rear of the spray gun, forcing the packing
assembly out. Be sure to remove all packing
contents from the fluid tube (See Figure 16).
8. Inspect and clean the packing cavity inside the
spray gun.
If necessary, use a spray gun
cleaning brush to remove excess debris.
For customer service call 888.389.2732
(continued)
!
screw
by
turning
Figure 14
Figure 15
Figure 16