Maintenance Guide
The DUX Automatic spray gun is a precision
tool that delivers superior finishing results and
cost savings with each use. Optimal results
require good handling and maintenance
processes.
Daily cleaning, lubrication, and proper
maintenance are required to maintain
the warranty coverage.
Lubrication
To ensure the quality and longevity of the
DUX spray gun, it must be lubricated before
every use and after every cleaning. Follow
the
diagram
below
lubrication (Use DUX lube—part # 310206).
Figure 5: Unscrew trigger housing
Lubrication areas
Figure 6: Lubricate thick part of needle
and needle o-rings
Figure 7: Lubricate the trigger piston
For customer service call 888.389.2732
to
ensure
proper
Trigger
Piston O-Ring
Fluid Needle Removal
!
NOTE: Due to the self-cleaning nature of the
fluid tip and needle combination; it is imperative
that both parts are changed together when
increasing or decreasing the fluid tip size.
To replace or change the fluid needle:
1. Ensure both fluid and air are depressurized.
2. Unscrew the fluid control knob by turning
counter-clockwise and completely removing
it, along with the fluid needle, from the
trigger housing.
3. Unscrew the spring cap from the fluid
adjustment knob (See Figure 8).
!
CAUTION:
The needle spring is under
pressure and is retained by this cap. It may
spring free when the cap is removed.
Figure 8
4. Remove the needle spring.
5. Remove and replace the needle.
6. Lubricate needle as required and reinstall
needle assembly.
AUTOMATIC
Spring Cap
Page 7