Datastrip DSVII-SC 사용자 설명서 - 페이지 7

{카테고리_이름} Datastrip DSVII-SC에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Datastrip DSVII-SC 19 페이지.

6

Operation

Startup Sequence:
To begin operation, depress and hold the power button on the front of the DSVII-SC
Release the button when a single beep is heard.
Two additional beeps acknowledge that power has been activated. The keypad and LCD backlights will turn on.
The on-board firmware performs self-tests prior to loading WinCE and the application software.
7

Battery Charging and Replacement

®
The DSVII-SC
has internal space for up to two Li-Ion battery packs. Each pack provides
3000mAh of capacity. The unit can be operated with none, one, or two batteries installed.
One battery is standard.
Under normal operating conditions, the battery does not need to be removed. The DSVII-
®
SC
has an internal charging circuit that can maintain a proper charge on the batteries
whenever the unit is connected to the external power supply.
The batteries may be replaced by opening a battery-access cover on the rear of the DSVII-
SC
®
. A slotted screwdriver or almost any coin can be used to operate the ¼ turn fasteners
holding the battery compartment cover in place.
When replacing the battery, ensure that the battery contacts are aligned with the battery
terminals inside the unit. Replace the battery cover and tighten the screw (do not over-
tighten). Incorrect battery installation will render the unit inoperable until the battery is
properly re-installed.
+
Note: The charging time for a fully discharged battery will be approximately
2 hours (or 4 hours for two batteries).
DSVII-SC
User Manual, Version 1.11
®
Copyright © 2006 by Datastrip, Inc. All rights reserved.
Reproduction in whole or in part is prohibited.
7
®
unit.
DSVII-SC
®
Battery