Aussie Pumps RAPTOR EXTREME Series 안전 운영자 사용 설명서 - 페이지 7

{카테고리_이름} Aussie Pumps RAPTOR EXTREME Series에 대한 안전 운영자 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Aussie Pumps RAPTOR EXTREME Series 16 페이지. Mine boss hydro-blasters

August 2019
supply hose to machine. Use a 25mm (minimum)
hose . Flush out hose before connecting to remove
any obstructions.
Incoming water supply must deliver double the flow
of the machine. If questionable, check supply at
machine. If supply is insufficient, do not operate
from this outlet. Connect only to clean town water
supply.
Warning: Do not operate from tank or pond. Doing
so will cavitate the pump causing damage.
Cavitation or pump starvation is not covered by
warranty. Cavitation is a phenomenon causing
vacuum pockets to form within the pump that
eventually implode under pressure pitting the
internal pump surfaces.
C.

Before starting the machine

OPERATE IN WELL VENTILATED AREAS ONLY.
1. Ensure machine is level
2. Turn on water supply.
D.

Starting the engine

1. Connect supply hose, turn on water supply and fill
break tank. NOTE: Tap should be left fully open while
machine is running.
2. Turn on fuel valve.
3. Connect battery at battery isolator.
4. Ensure engine throttle is fully turned down.
5. Pull the gun trigger to expel air from the system.
Water will trickle from the end of the lance when all
the air is expelled.
6. Ensure emergency stop button is reset and open the
front of the control panel.
Emergency Stop Button
WORK SMART ... STAY SAFE
AUSSIE SAFE BLASTING
All Class B machines are fitted with a
mandatory emergency stop, as per safety
standard AS/NZS4233.1.
This should only be used in an emergency.
Australian Pump recommends de-throttling
the engine and running with no load before
shutting off the engine by selecting off
button.
| Aussie Raptor (Class B)... Operator's Instruction Manual
7. Pull trigger of gun while starting the engine.
8. Select 'Power ON' button on control panel and then
press the green start button. This will initiate the start
sequence checks and the engine will automatically
start once these are complete.
9. Release gun trigger.
10. Increase throttle to fully open position. End stop has
been set to maximum 2400 rpm. Do not adjust this
end stop.
11.
Check that there are no leaks in the line
connections, gun or power lance.
detected they must be fixed before using the
machine.
1.
3.
6.
10.
If the emergency stop button has been used, it
will need to be reset before the engine will
start again. To reset, turn the button clockwise.
WARNING Immediately after activating the E-
stop move control power button the OFF
position. Failure to do so could result in a flat
battery or shortened battery life.
Aussie Pumps
If leaks are
2.
4.
8.
7