Power Distribution Unit
Product Overview
1. Power LED
2. AC Power Input
3. Power Switch
4. DC Power Outputs
5. Ventilation Holes
6. Grounding Screw
7. Mounting Holes (underneath)
Note 1: Each output is rated for +12 VDC / 2A (24 watts)
maximum. If using DC power cables other than those
provided with this unit, use 18 AWG wire and observe
proper polarity as shown on page 4.
Note 2: WARNING: In order to ensure proper operation
and long term reliability, care must be taken to ensure
that the airflow is not restricted in any way.
Installation
1.)
Install the power distribution unit in a rack mount environment using DVI-7520-RMK (purchased
separately). Care must be taken to ensure that the airflow is not restricted in any way.
2.)
Connect the AC power input cable to a power source and to the power distribution unit.
3.)
Connect devices to be powered to the DC outputs of the unit using the appropriate power
supply extension cables (see page 4).
4.)
Turn the power distribution unit ON using the power switch at the rear of the unit. Check to
make sure the power LED on the front panel is lit.
5.)
The unit is ready for use.
Note 3: WARNING: The DVI-7520-PDU provides +12VDC outputs. Take care to avoid connecting any 5VDC
devices to these +12VDC outputs as this may cause damage and system failure.
Quick Start Guide
Continuously lit when unit is receiving power and switched ON.
Connect supplied AC power cord securely to unit.
This switch turns the unit ON / OFF. Lights red when turned ON.
(1)
2-pin Phoenix connectors. See page 4 for more details.
(2)
Allow airflow through the device.
Attach a ground (earth) connection to the unit with this screw.
Use the included mounting screws to attach the unit to a rack mount
kit (p.n. DVI-7520-RMK – must be purchased separately).
(3)
DVI-7520-PDU
Air ow Diagram
(2)
3