Displayed on the home screen
House temperature
at the keypad.
Optional features, if
in operation, appear
here.
Menu / On / Off
Turning the system ON or OFF:
Press and hold MENU to turn the system On or Off.
Fan Boost: (Activate by holding down
for 3 seconds) When in Fan Boost, the system will
operate at maximum speed (max air supply rate) for a set amount of time, and then it will revert
back to condensation control speed.
Standard features:
To access the standard features:
Press the MENU button. (This changes the screen to the
first menu). Then move the highlight by using
OK to enter that function. Press the MENU Button at any time to return to the previous screen.
Fan Settings:
Fan Tune: This allows you to adjust the condensation control fan speed (air supply rate)
by +/- 50%. The system operates at this speed constantly unless it is in Fan Boost or has turned
off because of a humid air supply (see Hum. Settings)
Note: Altering the fan settings will alter the behaviour of your system. If performance is reduced,
adjust this setting back to where it was originally set. If unsure please contact our service
department on 0800 387 387.
DVS® EC Reclaim Plus User Guide (Humidity Sensitive)
Filter change
indication (if it is
due) appears here.
Humidity Sensor
to select the desired function and press
Hum. Settings: For adjusting the sensitivity of the system to an air supply which is more humid
than the air inside the home.
Hum. Settings - Hum. Sens: Sets the level of sensitivity of the system to the supply air being
more humid than the air inside the home. Ranging from OFF, LOW, MED, Hi (high), V Hi (very high).
'Standard Setting = Hi'
Hum. Settings - Hum. Time: Sets the time the system will allow supply air to be more humid
than the inside air. So; this setting creates a delayed reaction, ranging from Instant, V Hi (15mins),
Hi (30mins), Med (45mins), Low (60mins).
Standard Setting = 'Instant'
Note: Altering the above Humidity Settings will alter the behavior of your system. If performance
is reduced, adjust this setting back to where it was originally set. If unsure please contact our
service department on 0800387387 before you alter any of the settings.
Utilities:
For access to: Setting the System Clock, turning the Backlight On/Off, setting System Timer,
resetting the Filter Timer, viewing Temperature and Humidity graphs and System Diagnostics.
Optional Features:
These include Summer Vent Bypass, Solar Gain and Tempervents (Air Warmers)
To access the optional features (if fitted):
Press the MENU button. (This changes the screen to the first menu) Then move the highlight by
arrows to select the desired option and press OK to select that option.
using the
Mode: The way you want the optional feature to be activated.
(Follow the prompts at the bottom of each screen when setting).
Fan Speed: (Summer Vent Bypass and Solar Gain only). The Fan Speed the optional feature will
operate at when it is active.
Remember: Where you leave the highlight, is the mode in which the feature will operate in. If a
feature is currently on (active), it will show on the home screen in red.