6. If your pool is equipped with a heater or salt chlorinator, make sure the
bypass valves are set to the correct position as per the settings when your
pool was commissioned.
7.
Observe your QuikClean system and note what it is doing. If you don't feel
it is operating correctly, please refer to Figure 9 for helpful suggestions on
how to return your system to peak operating efficiency and effectiveness.
8. If you require additional support, please contact our support team via:
https://quikclean.com.au/service-support

Common symptoms, probable causes and solutions

Figure 9 identifies common symptoms and probable causes of performance
issues, and recommends solutions to optimise system performance.
Symptom
Water Actuator
Valve does not
rotate.
Impeller is not
turning
Cleaning heads do
not come up all the
way.
Cleaning head(s) will
not go down.
QuikClean system
performance is not
the same as it was
when the pool was
first started up.
Probable Cause
Dirty filter and/or
baskets are full of debris.
Pause control is ON.
Return water is not properly
diverted to the QuikClean
system
Dirty filter and/or basket are
full of debris.
Return water is not properly
diverted to the QuikClean
system.
Debris is stuck in the head.
Dirty filter and/or basket are
full of debris.
Debris is stuck in the head.
Return water is not properly
diverted to the QuikClean
system.
Page 8
Solution
Empty all baskets and clean filter.
Ensure the pause control lever is in
the down position.
Position valves on return manifold to
direct 100% of the water flow to the
QuikClean System.
Empty all baskets and clean the filter.
Position valves on the return
manifold to direct 100% of the water
flow to the QuikClean System.
Remove cleaning head and flush it
with water, removing any debris that
may be lodged in the head. Check for
debris in the orifice and flow path.
Empty all baskets and clean the filter.
Remove the cleaning head and flush
it with water, removing any debris
that may be lodged in the head.
Check for debris in the orifice and
flow path.
Position valves on the return
manifold to direct 100% of the water
flow to the QuikClean system.