7.

Thermistor Input

Can be used to connect external thermistors to monitor external temperatures.
8.

Radio Control Input and BEC

The Pro-160 will accept a standard hobbyist radio control servo signal directly
from a receiver. The receiver should be connected to pins B, C, and D. Pin D is
linked to pin A by Lk1, this can be removed if a 4 wire radio connection is
required.
The Pro-160 is pre-programmed to work with the majority of radio receivers.
Profiles 7 and 8 are pre-configured for RC single ended and joystick use. But to
get the best results you may need to use the RC learn function to properly match
the Pro-160 to your radio system.
The RDO port can act as a BEC for currents up to 1A. Pin B of the adjacent BEC
port can be used in parallel to increase this to 2A if required.
PRO-160 V2.0 10/19
B & D - Thermistors 2 and 3 should be 4QD
part number 39-B0.
If the Pro-160 detects thermistor[s] it will show
the approximate temperature readings on the
display.