OPERATION
IMPORTANT: All signal source equipment should be adequately
earthed. This not only ensures your safety but everybody else's as well.
Faults can and do occur in mains connected equipment where the
chassis can become "live" if it is not properly earthed. In these instances,
the fault in a "floating" (ungrounded) piece of equipment will look for the
shortest path to ground, which could possibly be your amplifier's input.
If the fault current is large enough, it will destroy the input to your
amplifier and look for the next available path, which may be you!
Before making any connections to your AMP Series amplifier, observe the
following:
Ensure the mains voltage supply matches the label on the rear panel of your
•
amplifier (+/- 10%).
Ensure that the power switch is OFF.
•
Ensure that all system grounds (earth) are connected from a common point.
•
Avoid powering equipment within a system from multiple power sources that
may be separated by large distances.
Check the continuity of all interconnecting leads to your amplifier; ensure
•
that there are no open or short circuited conductors.
Ensure that the power handling of your load (speakers) can adequately cope
•
with the power output of the amplifier.
Before operating your AMP Series amplifier, ensure that:
The BRIDGE Switch is not engaged if you are not running the amp in
•
bridged mode.
PAGE 10
AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL
Powering Up
REMEMBER: The amplifier should be the last piece of equipment
that you turn on and the first piece of equipment that you turn off.
We recommend turning the attenuators on your amplifier down when
turning the unit on.
Sensitivity
Your amplifier is a linear device operating with a fixed input to output voltage
gain (less attenuation). The maximum output voltage swing is determined by the
applied mains voltage, load, load type and the duty cycle of the applied signal.
The input sensitivity for your AMP Series amplifier when the level control is at
maximum position (fully clockwise) and the VCA is disabled is nominally:
+2.2dBu (1.00 volts in) for rated power into a 4 Ohm load.
Each channel of your AMP Series amplifier has a nominal balanced input
impedance of 30kOhms (@1kHz) and should not present a difficult load for any
signal source.
Your signal source (i.e. the equipment feeding signal to the amplifier) should
have an output impedance of 600 Ohms or lower to avoid unwanted high
frequency loss in the cabling.