FAST EDDY'S BARBEQUE OVEN
MODEL FE750

GENERAL INSTRUCTIONS

• This unit must be electrically grounded in accordance to your local codes, or with the National Electrical
Code ANSI/NFPA 70-1990.
• Keep the oven free from combustible materials. A good rule of thumb is to allow an 18" clearance
space around gear motor access panel and the fire pit door opening.
• Never store or use gasoline or other flammable material in the vicinity of this oven or use to ignite fuel
for this oven.
• Whenever working on, or servicing this unit ALWAYS disconnect the power.
• This oven is equipped with a 3 prong plug for your protection from a shock hazard. Always plug this
unit directly into a properly grounded 3 prong receptacle.
• WARNING! Exterior surfaces may be hot!
• Make sure all personnel are instructed on the proper use of the oven.

INSTALLATION INSTRUCTIONS

• Stationary installation should be on a level surface that can support a minimum weight of 2500 pounds.
• Visually inspect the cooking racks and carousel to ensure proper position prior to turning on the oven
after it has been transported.
• Ventilating air must not be obstructed from reaching the barbecue oven.
• Adequate make-up air and ventilation are required for the proper operation of burner and cooling of
motors.
• This unit must be properly vented and in an area where there is sufficient fresh air to prevent a
concentration of carbon monoxide from occurring.
• Chimneys are 5 inches in diameter and are required to extend 3 feet above the highest point where they
pass through the roof and at least 2 feet higher than any portion of a building within 10 feet. A rain cap
must be utilized on a chimney exhaust. A 4 foot flue extension is required for all units used outdoors.
Your flue extension rests inside the flue collar.
• Flues should be inspected and cleaned every six months.
Fast Eddy's Model FEC750
www.cookshack.com