1
Mic In
Balanced XLR microphone input.
Mic Signal
2
Green LED Signal Present indicator for the Mic input. It
indicates signal present on the input and is not affected
by the level control.
Line In
3
Balanced XLR line level input.
Line Signal
4
Green LED Signal Present indicator for the Line input. Indicates
signal is present at the input, it is not affected by the level control.
Line Out
5
LINE OUT is a line level output. This output can be connected
to the LINE IN on another XRS Powered speaker to expand
the system.
Output Clip
6
Red LED clip indicator for mixed mic and line audio signals.
Some flashing of red is acceptable on program transients.
Continuous flashing of red could indicate that undue stress
is being placed on the speaker and will sound distorted.
Turn down the input level until the clip LED is no longer lit.
7
Mic Level
Controls the level of the MIC input (1).
Mic Bass
8
Bass control for the MIC input (1). There is 12 dB of cut
and boost at 100 Hz. This EQ is the shelving type.
Mic Treble
9
Treble control for the MIC input (1). There is 10 dB of cut
and boost at 10 kHz. This EQ is the shelving type.
Line Level
10
Controls the level of the LINE input. (3)
MOUNTING
When mounting XRS series loudspeakers the following
safety issues must be considered;
1. The mounting of a permanently installed speaker may be
dangerous unless undertaken by a qualifified professional
with relevant experience.
2. Walls and mounting surfaces must be capable of supporting
the speaker and bracketry in a safe and secure manner.
3. Fixings must be safely attached to the speaker cabinet
and the mounting surface. All fixings must be installed
in accordance with the manufacturer's instructions and
specifications.
Line Bass
11
Bass control for the LINE input (3). There is 12 dB of cut
and boost at 100 Hz. This EQ is the shelving type.
Line Treble
12
Treble control for the LINE input (3). There is 10 dB of cut
and boost at 10 kHz. This EQ is the shelving type.
Power Switch
13
Mains power switch to turn the speaker amplifier on and off.
14
IEC Mains Input Socket
XRS series powered speakers use a standard IEC 3 pin mains
socket. A standard IEC mains cable is provided. The fuse drawer
contains the mains fuse and a spare. The mains fuse is a time lag
(slow blow) HRC 20 x 5 mm ceramic or glass type fuse.
XRS8P
XRS10P
115 V
2.5 A
2.5 A
230 V
1.6 A
1.6 A
IMPORTANT: Always replace the fuse with one of the same
value and type.
NOTE: Always disconnect power to the amplifier before
replacing fuses.
15
Voltage Select Switch
This switch selects the mains voltage for your region.
Choose either 230V or 115V.
IMPORTANT: Disconnect power to the amplifier before
operating this switch.
IMPORTANT: Always ensure that the correct voltage for your
area has been chosen before connecting the unit to the mains
supply. Failure to do so may result in personal injury or damage
to the unit.
Suspending with Eyebolts
As many eyebolt locations as possible should be used on
the speaker.
XRS6ODV or XRS8 speaker cabinet, at least two or more
mounting points must be used.
XRS10 and XRS12 speaker cabinets, three or more points
must be used.
The best way to hang a speaker using eyebolts is to use two
eyebolts on the top of the cabinet and one on the rear to give
the speaker some angle.
All eyebolt fittings in the XRS range are M8 and require at least
a 20 mm of thread length.
XRS SERIES INSTALLATION AND OPERATION MANUAL
XRS12P
3.15 A
5.0 A
7