4.6.

Central Master Clock

Figure 15 : Central Master Clock
The above network uses a repeater site to pass Framed E1 to two sites. One radio at the repeater site is
set to "Internal" and is the clock source for the entire network.
As in previous examples Framed E1 needs to have external clocking used. So each radio pair going to
Remote 1 and Remote 2 have the clocking set to External and Link.
Aprisa XE Clocking Technical Paper
13 | 15
Issued by: 4RF Customer Services 15 January 2009