Australian Pump Industries Clean Air Drum Vac 매뉴얼 - 페이지 2

{카테고리_이름} Australian Pump Industries Clean Air Drum Vac에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Australian Pump Industries Clean Air Drum Vac 4 페이지. Industrial wet/dry

NEW CLEAN AIR MODELS VC44, VC72, VC73,
Congratulations on choosing an environmentally friendly Aussie Eco-Clean Product.
FREE AUSSIE MICROWEB FILTER
with a microporous membrane applied to the collection surface. This provides a low pressure drop, improved dust
caking, better dust release and improved collection efficiency.
Microweb is used with dust from limestone, biochemical, lead, sugar, cement precious metals, pigments & fertilizers.
Before starting to use the machine, please note the following points and read these safety
instructions.
If you should discover any damage when unpacking the machine, please inform your Aussie Eco-
Clean Distributor.
Certain parts may be packed in the tank to protect them from damage. These should be removed
before the cleaner is put into use.
The supply voltage must be 240V.
1.
SAFETY INSTRUCTIONS
1.1
Recommended Usage
This machine is designed for professional cleaning according to these instructions, in particular for
the removal of types of dust which may be dangerous to health (not asbestos material).
1.2
General Safety Instructions
This machine is designed and constructed using state of the art protective devices. Danger can
occur in spite of this, particularly in the case of careless operation or non-compliance with these
safety instructions.
Contact with electrical current carries the risk of electric shock with can result in serious injury or
even death. Never touch damaged cables. Always switch off and disconnect the power supply
before carrying out any work on the machine. Replace faulty cables immediately.
1.3
Improper Usage
Any usage of the machine for a purpose not covered under the "Recommended Usage" or
previously agreed in writing is not permissible. The use of the machine in an unserviceable
condition or not in compliance with the following is prohibited:
Protective devices must not be removed or bypassed.
Any conversion or modification of the machine is not permitted.
Defective supply cables are only to be replaced by original cables.
Coupling elements between mains supply and/or extension leads must be at least splash-
proof.
The machine is to be fitted with a 10amp rated plug for use with 1 or 2 motors and 15amp
rated plug for 3 motors.
Fabric filter must be in place in tank for dry vacuuming.
1.4
Operator Responsibility
It is the responsibility of the operator to ensure that:
The machine is used only by personnel who have been instructed in its handling and who are
authorised to use it.
The recognised occupational safety regulations are observed.
Any further national or internal company regulations are observed.
All users are acquainted with the safety regulations and trained in the use of the specific
machine.
Responsibility for the operation, maintenance and repair of the machine is clearly assigned
and observed.
Faults and damage are immediately notified to the Authorised Service Agent
The operator is advised to wear proper soled footwear when using the unit.
2
VC83/3, DRUM VAC
....
Its unique filter media is constructed from a homopolymer acrylic fibre
IMPORTANT
Danger – Electrical voltage/electric current
Aussie Eco-Clean Industrial Wet/Dry Vacuum Cleaners
May 2015