DIP Switch: please see below for the DIP settings:
DIP1
operates in riser mode
DIP2
Reserved
DIP3
Gain High
Note:
• Operation mode: Protection mode will be activated once its connected devices are
short circuited, and power supply for ABCD outputs will be turn off, the flashing in-
use indicator shows the distributor is in protection mode.
• Self-detection: System will auto check whether the short circuit is fixed or not, then
recover the power supply, and in-use indication will be turn off;
• Detection period: Self-detection will happen regularly as below, the in- use
indicator will flash rapidly three times when check happens;
st
1
detection will be happen in 10 seconds after short circuit;
nd
2
detection will be happen in 60 seconds after 1st detection;
rd
3
detection will be happen in 5 minutes after 2nd detection;
th
4
detection will be happen in 10 minutes after 3rd detection;
hereafter detection will be happen every 30 minutes;
th
5

3. Unit Mounting

DBC4R
DIN Rail Mounting
ON
OFF
operates in distributor mode
Default
Gain Auto
-3-