Austro Flamm 65x 사용자 설명서 - 페이지 6

{카테고리_이름} Austro Flamm 65x에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Austro Flamm 65x 10 페이지. Inserts
Austro Flamm 65x에 대해서도 마찬가지입니다: 사용 설명서 (17 페이지)

Austro Flamm 65x 사용자 설명서

8. initial startup

Remove all enclosed documents and accessory parts from the combustion chamber.
Carefully read this user manual.
The first operation of your fireplace should take place at the earliest 4 weeks after the completion of
its surroundings, so that all parts can dry out well.
The fire should be kept small during the first hour, please only increase the wood quantity slowly.
However the maximum amount of fuel per hour must not be exceeded at any time.
The odours occurring during the first operation are normal and result from the vaporisation of greasy
metal surfaces and binding agents of the varnish. These vapours are non-toxic, but displeasing. We
therefore recommend airing your rooms well during the first operation.

9. first firing

For the correct and safe operation of the fireplace it is necessary to mind the necessary feed pressure. It
is especially important to check the feed pressure, before each initial firing (after the summer break) or in
between-seasons (e.g. strong wind, fog, etc.). Hold a match or lighter close to the open insert door. If the
flame is not being dragged into the open door, a kind of draught boost must be induced by a strong heat
generation (e.g. by lighting paper or small kindling). If this cannot be done successfully, please do not
heat your fireplace!
• Turn the air flap operation knob to the right – position "+"
• Open throttle valve completely, if installed.
• Place the larger logs (1), approx. 2-3 pieces (beech, oak or birch) at the bottom and put the
smaller cleaved softwood (2) on top. Put some lighting aid (3) inbetween the cleaved
softwood. Never use petrol, spiritus or the like for lighting the fire.
• After approx. 5-10 minutes (when the logs have burnt well) the combustion air flap may
be shut approx. 50 % (operation now in middle position).
Close throttle valve (if installed) after approx 5-10 min by 50 % (turn handle to the left).

10. heating

• open the combustion air flap by maximum 50 % (knob in middle position), otherwise the fuel quantity
will burn down too fast and thus too high temperarures may occur.
• open throttle valve by 50 %, otherwise the fuel quantity will burn down too fast.
• all existing convection air in- and outlets must be completely open.
• put more wood into the fireplace after approx. 45 to 60 minutes.
3
2
1
6