Technische Daten
Isolationskoordination nach IEC 60664-1 / IEC
60664-3
Bemessungsspannung ....................................................................12,5 V
Überspannungskategorie/Verschmutzungsgrad ................................. III/3
Bemessungs-Stoßspannung. ............................................................800 V
Einsatzhöhe ..........................................≤ 2000 m über Meereshöhe (NN)
Versorgungsspannung
Nennspannung ............................................................................ DC 12 V
Betriebsbereich der Nennspannung ........................... DC 11,4 V...12,6 V
Nennstrom ...........................................................................................1 A
Fehlergleichstrom-Überwachungsmodul
Messbereich ................................................................................. 100 mA
Ansprechwerte:
Differenzstrom I
....................................................................... .DC 6 mA
Δn
Ansprechtoleranz I
.................................................................-50...0 %
Δn
Wiederzuschaltwert:
DC 6 mA ....................................................................................... < 3 mA
Eingänge/Ausgänge und Betrieb
Klemme C:
Max. Kabellänge (PP, CP) ...............................................................< 15 m
Eingang 1 und 2:
Eingangsspannung .................................................... DC 11,4 V...25,2 V
Eingangsstrom .................................................................... 1,7...3,8 mA
Max. Kabellänge zum RFID-Modul ...................................................< 3 m
Umwelt/EMV
Betriebstemperatur. ............................................................-30...+70 °C
Klimaklassen nach IEC 60721:
Ortsfester Einsatz (IEC 60721-3-3). ...........................................................
................................. 3K23 (außer Kondensation, Wasser und Eisbildung)
Transport (IEC 60721-3-2) .................................................................2K11
Langzeitlagerung (IEC 60721-3-1) .....................................................1K21
Mechanische Beanspruchung nach IEC 60721:
Ortsfester Einsatz (IEC 60721-3-3) ...................................................3M11
Transport (IEC 60721-3-2) ..................................................................2M4
Langzeitlagerung (IEC 60721-3-1) ....................................................1M12
Anschluss
Anschlusskabel .................................................................................. RJ45
Max. Länge Anschlusskabel .............................................................< 3 m
Anschlussart (Klemmenblock C) ...........................................Federklemme
CC612 Laderegler/ CC612 charge controller
Technical Data
Insulation coordination acc. to IEC 60664-1/IEC
60664-3
Rated voltage ...................................................................................12.5 V
Overvoltage category/Pollution degree ............................................. III/3
Rated impulse withstand voltage .....................................................800 V
Altitude ...........................................................................≤ 2,000 m AMSL
Supply voltage
Nominal voltage. ...........................................................................DC 12 V
Operating range of the supply voltage .......................... DC 11.4...12.6 V
Nominal current ...................................................................................1 A
Residual direct current monitoring module
Measuring range ........................................................................... 100 mA
Response values:
Residual current I
. ..................................................................... DC 6 mA
Δn
Response tolerance I
. .............................................................-50...0 %
Δn
Restart sequence value:
DC 6 mA ........................................................................................ < 3 mA
Inputs/outputs and operation
Terminal C:
Maximum cable length (PP, CP) ....................................................< 15 m
Input 1 and 2:
Input voltage .............................................................. DC 11.4 V...25.2 V
Input current ...................................................................... 1.7...3.8 mA
Max. cable length to RFID module ..................................................< 3 m
Environment/EMC
Operating temperature ........................................................-30...+70 °C
Climatic conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) .................................................................
.......................... 3K23 (except condensation, water and formation of ice)
Transport (IEC 60721-3-2) .................................................................2K11
Long-term storage (IEC 60721-3-1) ...................................................1K21
Mechanical conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) .........................................................3M11
Transport (IEC 60721-3-2) ..................................................................2M4
Long-term storage (IEC 60721-3-1) ..................................................1M12
Connection
Connection cable............................................................................... RJ45
Maximum length connection cable ..................................................< 3 m
Connection type (terminal block C) .............................Push-wire terminal
CC612(4G)_D00325_06_Q_DEEN / 06.2021