GAC EEG6550 Series 매뉴얼 - 페이지 4

{카테고리_이름} GAC EEG6550 Series에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. GAC EEG6550 Series 13 페이지. Enhanced electronic governor

GAC EEG6550 Series 매뉴얼
5
DISPLAY & CONTROLS
ParameTer valUe
Displays the value of a selected parameter or
live running parameter. This area will blink if a
system shutdown and restart is required.
SeconDarY ParameTerS
Pressing UP or DOWN arrow toggles through the
four secondary parameters: Engine Speed (RPM),
Duty Cycle (%), Actuator Current (Amps), Engine
Speed (Hz), Battery Voltage (V DC), Hour Meter
(Hrs) and Service Time (SHR)
overcUrrenT
If the EEG detects an actuator overcurrent
it will terminate power to the actuator, the
display will flash Actuator Current along
with the warning indicator. (Cycle power to
restart)
fUel lImIT
If the EEG detects that the FUEL LIMIT
setting has been exceeded, the display will
flash the FUEL LIMIT along with the warning
indicator. Parameters will be unchanged.
over SPeeD
OVER SPEED will blink when the unit is in over-
speed. (Cycle power to restart)
locK
Once the LOCK parameter on the main menu is en-
abled (ON), the display can be manually unlocked.
locking/Unlocking the Display
Press and hold both the UP and DOWN arrows
simultaneously for 3 seconds to UNLOCK or to
LOCK the display.
enD USer InTerface
PrImarY ParameTer valUe
(Blinks if restart required)
SeconDarY ParameTer
acTUaTor DUTY cYcle
100%= 11 Bars
90-99% = 10 bars
...
10-19% = 2 bars
1-95% = 1 bar
0% = 0 bars
enGIne SPeeD
Middle bar = set point
Top bar = Set point + 10 RPM
Bottom bar = set point - 10 RPM
QUIKSeT menU
One row of parameters is displayed at a time.
Row 2 Column 3
ParameTer UnITS
Displays the units for the parameter (e.g. RPM)
PrImarY ParameTer UnITS
EEG6550 Enhanced Electronic Governor 5-2020-A1
4
Governors America Corp. © 2020 Copyright All Rights Reserved
ParameTer aDjUST
Parameter
Increment a Parameter value:
Adjust Up
HOLD
and TAP
rapidly Increment a value:
HOLD
and HOLD
lock the Display:
Parameter
HOLD
and
Adjust
Down
colUmn SelecT BUTTonS
1
2
3
To change the displayed row of parameters:
Tap any
To view a parameter value in a selected row:
Hold
For: SPEED
Hold: Button 1
For: IDLE
Hold: Button 2
Hold: Button 3
For: FUEL LIM
Pressing either UP or DOWN arrow
moves the primary and secondary
parameters to the next parameter
set. The list is always traversed in
one direction.
PrImarY ParameTer (UnITS)
Engine Speed (RPM)
Duty Cycle (%)
Actuator Current (A)
Engine Speed (Hz)
Battery Voltage (V DC)
Hour Meter (Hrs)
Service Time (SHR)
SeconDarY ParameTer
Actuator Duty Cycle
Engine Speed relative to set point
Duty Cycle
or
or
for 2 seconds
PIB1118