ECO series
TROUBLESHOOTING
Anomaly
No atomization
Leakage from the
nozzle
10 - Instruction Manual
Problem / Solution
No pressure is getting to the gun
Check air system
Gaskets part. [O4] worn out
Replace gaskets part. [O4] worn out
The head part. [C5], the nozzle part. [C4] eand
the rod part. [C12] are worn out.
Replace the head part. [C5], the nozzle part. [C4]
and the rod part. [C12]
The product is exceeding the amount needed
Reduce the product passage
Lack of product (flow rate too low)
Add product or reduce atomization air pressuree
Missing product in tank or clogged pipes
Fill tank or clean up with solvent
Mounted handwheel part. [C9] worn out
Replace mounted handwheel part. [C9] worn out