WARNING:
Only qualified and trained operators should install, adjust or use the assembly power tool for non-threaded
mechanical fasteners.
WARNING:
Operator
WARNING:
It is required that eye protection, hearing protection and safety boots be worn at all times while handling this
equipment.
WARNING:
The users or the user's employer should assess specific risks that could be present as a result after each use
based on their application.
● Be sure there is adequate clearance for tool and operator's hands before proceeding. Keep fingers clear of
any moving parts. Keep fingers clear from fasteners and installed materials. Severe personal injury may result.
● Verify
Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by the tool
WARNING:
Do not pull rivet in the air. Personal injury from fastener ejecting may occur.
WARNING:
Air is exhausted from the bottom of the tool. Direct bottom of the tool (exhausted air) away from operator, other
persons working in the vicinity, foreign matter and liquid.
WARNING:
Do not carry from hoses or use as a hammer.
WARNING:
Do not use in explosive atmosphere.
WARNING:
Ensure air hose is securely connected to avoid possible hose whipping.
WARNING:
Always disconnect air supply when tool is not in use to prevent accidental start-up.
WARNING:
Be sure there is adequate clearance for tool and operator hands.
CAUTION:
Do not use beyond the design intent.
The tool is shipped with a red plastic plug in the air inlet connector. The connector has a 1/4-18 female pipe thread to accept user air
hose fitting. The tool comes with oil and is ready to use.
1. Remove red plastic shipping plug from air inlet (Swivel A-249) and screw in your quick disconnect (air) fitting.
2. Attach Deflector (200232) to rear of head cylinder assy (703109). Rotate deflector (200232) away from operator or other people
working in the vicinity.
3. Connect tool to air hose with 90 psi. (6.2 bar) (3/8 minimum diameter air line is mandatory, is recommended. Cycle tool five times
by depressing and releasing actuator. (Clean dry air is mandatory).
4. Disconnect air hose from tool.
5. Select proper nose assembly (see accessories pg. 18 for more information). Screw collet onto piston and slide anvil over collet
and secure with jam nut (70820). (See proper data sheet for further instructions.)
6. Connect air supply.
USER QUICK
DISCONNECT FITING
AIR HOSE
S/N: 3191 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
HOW TO SET-UP THE GB703
MUST
read and understand all warnings and cautions.
the air lines and/or hydraulic hoses are not a trip hazard.
DEFLECTOR
RED SHIPPING PLUG
AIR INLET
Image may not reflect actual tool
HEAD CYLINDER
8
NOSE ASSY
RIVET
WORK
ACTUATOR
4/12 Rev. 1/17