Gage Bilt GB206-500/25 사용 설명서 - 페이지 13

{카테고리_이름} Gage Bilt GB206-500/25에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Gage Bilt GB206-500/25 20 페이지.

Note: Gage Bilt does not recommend using a pneumatic lubricator or adding pneumatic oil to the air inlet on our tools or powerunits.
Stroke limiters are designed for the protection of the operator and equipment. Failure to operate tool with a stroke limiter as required
will result in damage to the nose assembly or tool and may result in personal injury. If you are unsure your nose assembly requires a
stroke limiter, contact Gage Bilt.
When a shorter-stroke (.375") tool is required, 206110 & 206112 relief valve & stroke limiter must be ordered. (Sold separately).
1. To re-assemble or disassemble stroke limiter (206112), see overhaul instructions (#1 thru #7) on pg.12.
2. To decrease stroke to .375" (9.5 mm), remove relief valve (206109) from piston assembly (206211). Install stroke limiter (206112)
and the relief valve (206110) (flats to rear of the tool) in the piston assembly (206211).
Do NOT position relief valve
flats to front of tool.
GB206-500/25 / GB206-500/25A INSTALLATION TOOL
STROKE LIMITER - INSTALLATION & REMOVAL
(For use when a shorter (.375") tool stroke is required).
Relief valve (206110) & stroke limiter (206112) (Sold Separately).
Stroke Limiter (206112)
Relief Valve (206110)
Front of tool.
Rear of tool.
Images may not
reflect actual tool.
13
Stroke Limiter (206112)
Piston Assembly (206211)
Position relief valve
flats to REAR of tool.
11/17 REV 4/23