Gage Bilt GB745SHAVT 원본 사용 설명서 - 페이지 8

{카테고리_이름} Gage Bilt GB745SHAVT에 대한 원본 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Gage Bilt GB745SHAVT 20 페이지. Installation tool

WARNING:
Only qualified and trained operators shall install, adjust or use the assembly power tool for non-threaded
mechanical fasteners.
WARNING:
Operator
WARNING:
It is required that eye protection, hearing protection and safety boots be worn at all times while handling this equipment.
WARNING:
The users or the user's employer must assess specific risks that could be present as a result after each use based on their
application.
● Ensure there is adequate clearance for tool and operator's hands before proceeding. Keep fingers clear of
any moving parts. Keep fingers clear from fasteners and installed materials. Severe personal injury may result.
● Verify that hydraulic hose fittings and couplings, air and electrical connections are secure.
● Verify
Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by the tool
Do not use as a hammer to force fasteners into holes or otherwise abuse tool.
WARNING:
Do not actuate fastener in the air. Personal injury from fastener ejecting may occur.
WARNING:
Ensure air hose is securely connected to avoid possible hose whipping.
WARNING:
Always disconnect air supply when tool is not in use to prevent accidental start-up.
WARNING:
Do not operate this tool without deflector, pintail catcher bag or pintail collection bottle in place
CAUTION:
Do not use beyond the design intent.
The tool is shipped with a plastic plug in the air inlet connector. The connector has a 1/4-18 NPT female pipe thread to accept end-user
air hose fitting. The tool comes with oil and is ready to use.
1. Remove red plastic shipping pipe plug (A-204) from air inlet on regulator (A-1291) and screw in your quick disconnect (air) fitting.
2. Open cap on top of oil reservoir and fill with AW-32 oil or equivalent to approximately 3/4 full, if required.
3. Connect the installation tools hydraulic line, air line, vacuum line and lanyard to powerunit. (Make sure all connections are secure).
4. Connect air supply using 1/2" (12.7 mm) air line min. Set air pressure to 90-100 P.S.I. (6.2-6.9 bar) Max. on regulator (A-1291).
5. Cycle tool five times.
6. Disconnect air supply.
7. Attach nose assembly.
8. Reconnect air supply.
USER QUICK
DISCONNECT FITTING
1/2" (12.7 mm)
AIR HOSE
GB745SHAVT INSTALLATION TOOL

HOW TO SET-UP THE GB745SHAVT

MUST
read and understand all warnings and cautions.
the air lines and/or hydraulic hoses are not a trip hazard.
ATTACHING NOSE ASSEMBLY:
MAY VARY DEPENDING ON NOSE OR TOOL)
(
(SEE DATA SHEET FOR COMPLETE
REMOVE THE A-204 RED
SHIPPING PIPE PLUG
AIR INLET
A-1291
REGULATOR
ASSEMBLY INSTRUCTIONS)
Image may not reflect actual tool
8
AIR OUTLET
AIR LINE FROM TOOL
HYDRAULIC LINE
FROM TOOL
HYDRAULIC OUTLET
7/21 REV 5/22