Active Silicon HARRIER 18x AF-ZOOM HMDI 4K CAMERA 빠른 시작 매뉴얼 - 페이지 4
{카테고리_이름} Active Silicon HARRIER 18x AF-ZOOM HMDI 4K CAMERA에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Active Silicon HARRIER 18x AF-ZOOM HMDI 4K CAMERA 9 페이지.
Setting up the System
To get the Harrier 18x AF-Zoom HDMI 4K Camera running, please follow the instructions below
(also see figure 3):
1. To mount the evaluation board on to the camera please see the section 'Mounting the
Harrier 18x HDMI 4K Camera Evaluation Board onto the camera' below.
2. Connect the 24-way FFC cable to the camera (J3 – J302).
3. Connect the 30-way KEL cable to the camera (J2 – J301).
4. For capturing analog camera output connect the BNC socket (J7) on the evaluation board
to an analog monitor/display using a suitable coaxial cable.
5. For HDMI camera output, remove the protective insert from the HDMI socket (J4) and using
a suitable HDMI cable, connect the evaluation board to a HDMI monitor/display. If you
intend to use 4K, the monitor and cable will need to be able to support 4K video.
6. For VISCA communications with the camera, use the mini USB–USB Type-A cable to
connect the mini USB socket (J6) on the evaluation board to a PC. The VISCA interface will
appear as a COM port on the PC and be accessible to PC software; this COM port can be
used with the
HarrierControl
communicate with the camera. The HarrierControl application can be downloaded from
www.activesilicon.com
7. Set the evaluation board power switch (SW1) to OFF (left viewed from above).
8. Connect the power supply barrel connector to the evaluation board power input connector
(J1).
9. Plug in the power supply and switch ON the evaluation board power switch (SW1). The
Power LED (LED1) should light up.
10. The camera will make audible mechanical noises as it goes through its power-up sequence
and after a short time the video outputs will start working.
Note: the camera will power up in the last video mode used, some monitors cannot display
all the modes supported by the camera (notably 1080p30 and 4K). If you have no visible
video output, use the HarrierControl application to check/change the video output mode set
on the camera to ensure that the camera output is supported by the monitor.
11. If an analog monitor is connected to the evaluation board, and the camera analog output is
enabled, you will see the camera output on the analog monitor.
12. If the HDMI output is connected and set to a supported mode, you will see the camera
output on the HDMI monitor/display.
September 2021
HARRIER 18x AF-ZOOM HMDI 4K CAMERA
command line software, or other serial control applications, to
from the
Software
page.
QUICK START GUIDE
Version 1.0.0 - September 2021
Page 4 of 9