Gage Bilt GB50 원본 사용 설명서 - 페이지 4

{카테고리_이름} Gage Bilt GB50에 대한 원본 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Gage Bilt GB50 9 페이지. Pneumatic installation tool

When the lever assy (1) is depressed, the pressurized air inside the tool is directed to the front side of the piston (3) thus moving it
to the rear of the head cylinder assy (2), forcing the air from the back side of the piston (3) to be exhausted from the side of tool.
The internal components of the attached nose assembly are simultaneously moving with the piston (3) to start the fastener
installation. When the fastener installation is completed, the lever assy (1) is released directing the air to the back side of the
piston (3) reversing the sequence.
3
2
1
Piston in forward position
STANDARD
EXHAUST
(Side of tool)
OPTIONAL
EXHAUST
(Rear of tool)
GB50 S/N: 1476 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
PRINCIPLE OF OPERATION
3
2
1
Air is exhausted through
Standard Exhaust Port
on side of tool.
Air is exhausted through
Rear Exhaust Port
4
Piston in rear position
Rear Exhaust Port
Plugged
Rear Exhaust Port
Plug removed
Rev. 5/15