Hi-flying Elfin-EE10 운영 매뉴얼 - 페이지 7

{카테고리_이름} Hi-flying Elfin-EE10에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Hi-flying Elfin-EE10 15 페이지. Rs232/rs485 to wi-fi

Hi-flying Elfin-EE10 운영 매뉴얼
Operation Guide
Elfin-EE1X

3. TEST EXAMPLE

Elfin-EE1X use TCP/IP protocol for communication. There is two main parameters one for IP address
and another for port number.

3.1. Ethernet Direct Connect Networking

Auto-IP is used for local area when there is no DHCP server exist, devices will use the Class B
169.254 for communication. Connect device Ethernet with PC, the device will use default auto IP(Elfin
series use 169.254.1.1, others use 169.254.173.207). The PC may use this IP to config the device or
transfer data. As the following example
Step 1:Open IOTService and find the device.

3.2. TCP Server Test in Auto IP Mode

Step 1:Open TCP&UDP test tool and generate TCP connection as following steps. Device has
already created a TCP Server (port 8899) for use. TCP&UDP test tool can be downloaded from our
website:
DestIP:IP address of device which can be found by IOTService.
Port:Port of TCP Server which can be found by IOTService or set by users own.
http://www.hi-flying.com/
- 7 -