5.3.1 Connections
Connections between couplers (see fig 5.1) are made by [1] pulling back the spring collar on the female
coupler. [2] Inserting the male coupler into the female coupler and then releasing the female spring collar.
[3] Lock the connection by (1) pushing forward on the locking-collar and then (2) twisting it clockwise and
releasing. A gentle tug on the hose should be enough to make sure the hose is correctly connected.
Disconnections are the reverse of the above process.
5.3.3. Connecting a Bolt Tensioner / Hydraulic Nut to the Pump
NOTE: For full details on how to connect a bolt tensioner/ hydraulic nut to the pump, refer to the operating
manual of the tool being used.
5.4 Filling the Air Supply Lubricant Reservoir
IMPORTANT:
The AHP-BTU Series Air Motors require ISO VG 32 (SAE10) Oil.
Turn Off or Disconnect from the Air Supply.
Remove the Air Lubricator Filler Plug (17).
Fill the Air Lubricator Reservoir (18) with ISO VG 32 (SAE10) Oil to the fill line marked on the
reservoir.
Replace the Air Lubricator Filler Plug (17).
5.5 Air Supply Requirements
The air supply must be delivered via a suitably rated air hose of at least 1/2" (13mm) diameter.
The air supply pressure must be at least 5.5 bar (80 psi), but preferably 7 bar (100 psi).
The compressor must be able to maintain a minimum flow rate of 50 cfm (24 l/sec).
Operating Instruction Manual:
OM-AHP-BTU-01
Fig 5.1: Hydraulic Connections
10
Serial Numbers:
FROM BQ 9522