Hi-Force HP110 사용 설명서 - 페이지 9

{카테고리_이름} Hi-Force HP110에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Hi-Force HP110 13 페이지. Manually operated hydraulic pump - steel
Hi-Force HP110에 대해서도 마찬가지입니다: 작동 지침 (4 페이지), 사용 설명서 (6 페이지)

Hi-Force HP110 사용 설명서
To do so: Ensure that all threads are clean with no damage [1] Press the male coupler into the female
coupler, [2] then turn the threaded-collar clockwise (by hand) until the threads are fully engaged.
IMPORTANT:
Make sure that all coupler threads are fully engaged.
Only use hoses with a 4:1 safety rating on burst pressure.
6.4 Bleeding Trapped Air from the Hydraulic System
The bleeding of trapped air from a hydraulic system must only be performed by qualified
personnel who have been trained and are competent to do so.
The method of air removal will depend on the hydraulic system under test. Safe, effective methods of air
removal, must be established before starting any operation. Pressure testing with air trapped in the hydraulic
system can lead to an increased risk to the equipment and the operator.
NOTE: To reduce the likelihood of introducing air into the hydraulic system, make sure that all hoses are
pre-filled with fluid before connecting them to the hydraulic system.
Cylinder and hoses are not always completely filled with oil when new. For safe and efficient operation,
trapped air must be removed from the system. The following procedure must be carried out with the
cylinder/s connected to the pump, but not operating under load.
To remove air from the system, proceed as detailed below:
Figure 5.2
Make sure the pumps oil filler breather cap is fitted. (if applicable)
With all hydraulic connections made, position the cylinder/s below the level of the
hydraulic pump, as illustrated in figure 5.2.
Using the pump, fully advance and retract the cylinder/tool piston several times
until the operation is smooth. (Refer to the pumps operating
manual for details of pump operation).
Operating Instruction Manual:
OM-HP-STEEL-01
9
Serial Numbers:
From: DF6685