Force repair centres. The following table gives possible causes and solutions for common problems.
Problem
1. Pump will not start
2. Motor stalls before full
operating pressure is
reached.
3. Pump runs but will not
build up to full operating
pressure.
4. Noisy Operation
Refer to the nameplate on the pump for model identification.
Motor
Motor
Voltage
Frequency
110V-1Ph
50 Hz
120V-1Ph
60 Hz
230V-1Ph
50 Hz
220V-1Ph
60 Hz
400V-3Ph
50 Hz
460V-3Ph
60 Hz
9.0 Troubleshooting
TROUBLE SHOOTING GUIDE
Possible Cause
a. Power not connected.
b. Damaged power cord.
c. Circuit breaker tripped.
d. Damaged pendant.
e. Blown fuse.
f. Burnt out motor.
a. Low supply voltage.
a. Reservoir breather has not been
installed.
b. Low oil level.
c. Adjustable relief valve incorrectly set.
d. External oil leak in system.
a. Air trapped in the system.
b. Low oil level
c. Reservoir breather has not been
installed.
Operating Instruction Manual:
OM-HPF PUMP-01
Motor
Current
16 A
23 A
9.3 - 9.6 A
12.7 A
3.6 A
3.2 A
Solution
Connect power.
Repair or replace power cord.
i. Reset Circuit breaker.
ii. Ensure breaker is adequately rated.
Contact your local Hi-Force office/distributor.
Replace blown fuse.
Contact your local Hi-Force office/distributor.
i. Use heavier gauge extension cord.
ii. Turn off excess electrical loads.
Remove transit plate and install reservoir
breather as per section 5.1
Add oil as per section 5.2.
Adjust relief valve pressure as per
section 6.1.
Contact your local Hi-Force office/distributor.
Bleed air from the system as per section 5.4
Add oil as per section 5.2
Remove transit plate and install reservoir
breather as per section 5.1
14
From Serial Number:
BS8412
Motor
Output
1.1 kW
1.8 kW
1.5 kW
1.8 kW
1.5 kW
1.5 kW