AVOID RESTARTING THE COMPRESSOR WITHIN 3 MINUTES OF TURNING OFF
HEATING: (ref fig.16)
NB. The unit will not heat if inside temp. is much above 28°C.
1. Turn fan speed selector to
2. Turn mode selector to
3. Adjust the thermostat to max. clockwise position.
There will be approximately 30 seconds delay before heating is apparent.
4. Gradually over time, adjust the thermostat until comfortable conditions are maintained.
Condenser set:
Height
-
Width
-
Depth
-
Weight -
Air Handler:
Height
-
Width
-
Depth
-
Weight -
Minimum cupboard dimensions:
320 high x 525 wide x 340 deep
Cooling output:
Heating output:
Maximum current (cooling):
Maximum current (heating):
Maximum locked rotor current:
(Heating Speed)
(Heating)
UNIT SPECIFICATIONS
250 mm Above floor
465 mm
440 mm
30 kg
240 mm
385 mm
250 mm
4 kg
2.2 KW
1.5 KW
4.0 amps
6.5 amps
19 amps
Refrigerant: Australia only
Euro production
Charge:
Air volume (max) Air Handler: 110 l/s
Fan (Air handler):
Resistance run wdg.:
Resistance aux wdg.:
Capacitor:
Fan (Condenser set):
Resistance run wdg.:
Resistance aux wdg.:
Capacitor:
Heating element:
Refer fitting instructions included
8
R22 or 407C as marked
R407C
700 grms.
165Ω
265Ω
1.5 mfd. 440 vac
168Ω
150Ω
2.5 mfd. 440 vac
1500W
(Pt. No. 4002024)