Aircommand IBIS 설치 및 운영 지침 매뉴얼 - 페이지 6

{카테고리_이름} Aircommand IBIS에 대한 설치 및 운영 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aircommand IBIS 15 페이지.

Aircommand IBIS 설치 및 운영 지침 매뉴얼

1. INSTALLATION POSITION

Minimum 25mm clearance from
side grills to any obstruction
Minimum 200mm clearance from
rear grills to any vertical face
Minimum 100mm clearance to any
45 degree face
Before beginning, mark out the position of the unit
considering the following important requirements:
- The air conditioner should be situated as
centrally as possible on the van, to ensure even air
distribution.
- The front of the unit MUST face the direction of
travel, failure to follow this instruction will result
in damage to the condenser fans.
- If the caravan is over 23' in length, or has an
unusually high heatload, Aircommand would
recommend 2 or more units to cool effectively.
- When considering the installation position
remember to check for clearance around the
plenum inside the van.
- Avoid an installation position where a bulkhead,
cupboard or light fitting could interfere with the
discharge air flow from the plenum.
It is important that the unit is never
more than 5° from the horizontal and the
rear of the unit should never be higher
than the front
- Contact Aircommand if your installation differs
significantly
DIRECTION OF TRAVEL
Fig 2: The foot print of the rooftop unit, and the plenum, measured from the hole
- The above outline on the left shows the minimum clearance required around the
IBIS unit on the roof of the vehicle, distances shown are calculated from a 14"
square hole (356 x 356mm)
- The above outline on the right shows the minimum clearance required around
the Plenum located on the ceiling inside the vehicle, distances shown are
calculated from a 14" square hole (356 x 356mm)
REAR OF UNIT
Fig 1: IBIS Vent clearances
DIRECTION OF TRAVEL
Note position of twin condenser exhausts
Hot air is ejected from these exhausts;
consider hatch positions at rear of unit
DIRECTION OF TRAVEL
14" x 14"
(356mm)
SQUARE
HOLE