Gaggenau VG 232 AU 지침서 - 페이지 17

{카테고리_이름} Gaggenau VG 232 AU에 대한 지침서을 온라인으로 검색하거나 PDF를 다운로드하세요. Gaggenau VG 232 AU 19 페이지. Built-in gas cooktop
Gaggenau VG 232 AU에 대해서도 마찬가지입니다: 지침서 (19 페이지)

Gaggenau VG 232 AU 지침서
Fig. 11
See table on Page 12 for details of nozzle
settings.
All manuals and user guides at all-guides.com
Replacing the main nozzle 2
Proceed as follows:
– The main nozzle 2 is visible after detaching the
burner cover (see Fig. 11). It is unscrewed with a
special screw key.
– Unscrew the nozzle and insert the new nozzle as
specified in the main nozzle table. The nozzle
must be screwed in fully and firmly (torque
1.5 Nm) (metallic seal).
– Please do not forget to stick the new adhesive
label included with the nozzle set over the old
adhesive label on the gas connection, thus
documenting the changeover to a different gas
type.
Checking functions
The flames are adjusted correctly if no yellow tips
are visible and if they do not go out when switching
over swiftly from the high to the low setting.
Adjusting the primary air
The primary air setting for different gases is only
defined by the diverse nozzle shapes and therefore
does not require adjustment.
17