ACTIVE STATION ASWD2001 소유자 매뉴얼 - 페이지 12

{카테고리_이름} ACTIVE STATION ASWD2001에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ACTIVE STATION ASWD2001 15 페이지.

Error 
Cause 
code 
E01 
No sensor signal 
Over‐voltage protection of the 
E02 
motor 
E03 
Over‐current protection 
E04 
Open circuit 
E06 
Message failure 
E07 
Emergency switch off 
 
TROUBLESHOOTING GUIDE 
Checking 
1. Check the distance and 
place between sensor and 
magnet. 
2. Check if the wire is broken. 
3. Check if the magnetism is 
good. 
4. Check if the controller is 
damaged. 
1. Check if the network 
voltage is stable. 
2. Check if the controller is 
damaged. 
1. The machine is overloaded. 
2. Check if the motor or the 
roller gets stuck by 
something. 
3. Check roller lubrication. 
4. Check if the controller is 
damaged. 
5. Check if the motor is 
damaged. 
1. Check the wires of the 
motor are connected well. 
2. Check if the motor is 
open‐circuit. 
3. Check if the controller is 
open‐circuit. 
1. Check if the connecting 
wires are plugged well. 
2. Check if the connecting 
wires are broken. 
3. Check if the console is 
broken. 
4. Check if the controller is 
damaged. 
1. Check if the emergency 
switch is attached. 
~ 12 ~
Correction 
1. Adjust the distance 
between the sensor and the 
magnet. 
2. Change the wire. 
3. Change the magnet. 
4. Change to a new controller. 
1. Regulator is needed to 
adjust the voltage. 
2. Change to a new controller. 
1. Verify user weight is within 
allowed parameters 
2. Take the foreign matter 
out. 
3. Lubricate the roller. 
4. Change to a new controller. 
5. Change to a new motor. 
1. Connect the motor wires 
properly. 
2. Change to a new motor. 
3. Change to a new controller. 
1. Plug all the wires properly. 
2. Change to the new wires. 
3. Change to a    new console. 
4. Change to a new controller. 
1. Attached the emergency 
switch.