The explanation of the parameters involved in the upper computer tool interface is detailed in Table 4-
2.
Parameter
Name
Used to set the minimum distance gate for radar detection.
Minimum
Distance
Used to set the maximum distance gate for radar detection.
Maximum
distance
The target state is switched from occupied to unoccupied with a
Target
disappearance
unoccupied and report unoccupied if it detects unoccupied for a
Delay time
occupied, which is more than 5 times the noise level. Please
Trigger
Threshold
The sensitivity for detecting human micro-movements and
maintaining the presence of a person is recommended to be
Maintain
threshold
4.2.3 for the scanning and data viewing of the bottom noise.

4.2.2. Bottom noise scanning

The Uplink Bottom Noise Scan page is shown in Figure 4-3. Scanning the bottom noise through
the Uplink is divided into three steps:
Step 1: Set the scan interval and scan duration.
Step 2: Set the path to save the data files.
Step 3: Click "Start Scan".
The noise data is stored as a folder in the set file path with a timestamp added to the folder name
suffix for differentiation. No one is kept in the scan area during the scan noise.
HLK-LD2420
Table 4-2 Explanation of the parameters of the upper computer tool interface
Explanation
The resolution of the distance gate is 70 cm.
The resolution of the distance gate is 70 cm.
delay of T: during this time, if an occupied state is detected, the
timing of this period is restarted. The radar will only switch to
full T time.
It is recommended to set the sensitivity from unoccupied to
refer to 4.2.2 and 4.2.3 for bottom noise scanning and data
viewing.
set at 2~5 times the noise level. Please refer to 4.2.2 and
第 7 页 共 14 页
User Manuals
Parameter Range
0~15
0~15
(need not be less than the
minimum distance)
0~65535
0~65535
0~65535