Gaggenau AH 590-120 원본 작동 및 조립 설명서 - 페이지 15
{카테고리_이름} Gaggenau AH 590-120에 대한 원본 작동 및 조립 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Gaggenau AH 590-120 18 페이지. Freely suspended insular hood
Gaggenau AH 590-120에 대해서도 마찬가지입니다: 작동 및 조립 지침 매뉴얼 (18 페이지)
Installation above gas cooker / gas hob
Installation of the appliance above a gas cooking
device must conform to national safety regulations
(e.g. in UK CORGI standards).
A minimum distance of 700 mm between the hood
and gas appliance must be observed.
Gas appliances may only be used under the
extractor hood when pots and pans are placed on
them!
Operation above gas cooker / gas hob
During operation the heat load of all hotplates and
oven must not exceed 13.5 kW.
Should the nominal heat loads of all hotplates com-
bined exceed 13.5 kW (e.g. combination with WOK
burner), during operation only a combination of hot-
plates of max. 13.5 kW must be used.
Exception:
the nominal heat loads of all hotplates combined to
a maximum of 15.4 kW can be operated for a very
short period of time (max. 15 minutes), if the hood is
running on a minimum of level 2. Otherwise there is
a risk of burns when touching the exterior of the ex-
tractor hood.
14
The following note applies to extractor hood
AH 592-120 only; this model does not have an
integrated fan:
The extractor hood can only be used in exhaust air
mode. The exhaust air is conveyed upwards through
an externally attached fan via a ventilation shaft or
directly into the open air through the outer wall.
The extraction function is realised by an external
fan module. We recommend the fan modules
GB 032-107 or GB 052/053-140 from our Gaggenau
range; the extractor's electronic circuitry is
optimised for these fan modules.
For the electrical connection between the extractor
hood and external fan see installation instructions
for the external fan.
For safety reasons, if the connecting cable to
the external fan has been damaged, it must be
replaced by the manufacturer or the after sales
service or similarly qualified persons.