5. Maintenance

Fig. 15
Fig. 16
First disconnect the appliance from the mains
before carrying out any repairs.
In the event of malfunctions, first of all check
the household fuses.
If the power supply is in proper working order,
but the appliance is nevertheless not functioning,
then please contact your specialist dealer or your
responsible Gaggenau after-sales service.
Specify the appliance type (see rating plate).
Repairs must only be carried out by authorised
specialists, thus ensuring the safety of the
appliance. Improper tampering will render all
warranty claims null and void.
Lamp replacement
Caution: Disconnect the power supply before
replacing lamps!
Caution: Lamps may still be hot shortly after use!
Risk of burns.
– Remove the grease filters.
– Remove the screws on the lamp cover. The lamp
cover tilts down and cannot be removed from
the appliance (Fig. 15).
– Turn the lamp to the left and remove the lamp
(Fig. 16).
Defective lamps must only be replaced by lamps
of the same type (Cool Beam)! You can obtain
the original spare part (No. 03602611) from trade
dealers or via Gaggenau after-sales service.
Inserting the lamp
– Insert the lamp and turn it to the right.
– Screw down the lamp cover again.
– Connect the appliance to the mains again.