Operating Principle

The backsplash ventilation is an effective air
recirculation system, which extracts the vapors
directly behind the cooktop towards the rear. The
centrifugal grease filters separate the greasy
components from the extracted air. The grease is
collected in the trays. The grease fine filter absorbs
any remaining grease particles. The activated
carbon filter in the fan housing traps odors, the
exhaust outlet for the clean air is in the furniture
cabinetry toekick.
air intake
centrifugal grease filters
grease fine filter (fleece filter)
grease collecting trays
fan housing
activated carbon filter
exhaust outlet
9