Gaggenau AW 400120 작동 및 설치 지침 - 페이지 15
{카테고리_이름} Gaggenau AW 400120에 대한 작동 및 설치 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Gaggenau AW 400120 20 페이지.
Electrical connection
•
Before connecting the appliance to the power
supply, always follow the instructions and
warnings in the chapter entitled "Safety
instructions"!
•
The extractor hood may only be connected by a
qualified electrician who is familiar with the
regulations of the relevant electricity supply
company.
RISK OF INJURY
•
If the power cord of the extractor hood is
damaged, it must be replaced by the
manufacturer, his customer service or a
similarly qualified person to prevent hazardous
situations.
•
The extractor hood may be connected to a
correctly installed earthed socket only.
•
Attach the earthed socket as directly as
possible behind the flue duct.
–
The earthed socket should be connected via its
own circuit.
–
If the earthed socket is no longer accessible
following installation of the extractor hood, a
disconnector must be fitted as for a permanent
connection.
If a permanent connection is required
•
A disconnector must be provided on the
installation side. Switches with a contact
opening of more than 3 mm and all-pole
disconnection are regarded as disconnectors.
This includes LS switches, fuses and
contactors.
Electrical specifications
The required connection data can be found on the
rating plate inside the appliance when the grease
filters have been removed.
Length of the power cord: approx. 1.30 m.
This extractor hood complies with the EC
interference suppression regulations.
15