Great Outdoors A05714W 조립 및 사용 설명서 - 페이지 7
{카테고리_이름} Great Outdoors A05714W에 대한 조립 및 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Great Outdoors A05714W 18 페이지. X-series portable gas grill
Take These Instructions to the L.P. Gas Dealer
When using a cylinder exchange, be sure the
exchanged cylinder is a Type 1 cylinder; a 510
POL cylinder will not fit a Type 1 regulator.
FILLING AND PURGING
TYPE 1 L.P. GAS CYLINDERS
DANGER:
Purging and filling of L.P. gas
cylinders must be performed by personnel who
have been thoroughly trained in accepted L.P.
gas industry procedures. Failure to follow this
instruction may result in explosion, fire, severe
personal injury or death.
IMPORTANT:
Purge new cylinders before
filling. This tank is easily filled with a standard
CGA 510 POL filling connection.
CGA-510 POL
Filling a Type 1 Cylinder Valve
Example A: shows a CGA-510 POL fitting.
Example B: shows using a Type 1 POL fitting.
Type 1
(cut away to see fitting)
The L.P. gas cylinder has a Type 1 cylinder
valve with a back-check module in its outlet
that will not permit gas to flow until an
evacuation device is installed. To purge the
L.P. gas cylinder, the back-check module must
be opened with an evacuation device.
PURGING AND EVACUATION DEVICES
FOR L.P. GAS CYLINDER WITH TYPE 1
CYLINDER VALVES
A. Hose-end valve with a bleed port: Purging
can be accomplished using a hose-end valve
containing a bleed port, which also allows for
evacuation without the use of an adapter.
B. Hose-end valve without a bleed port:
When a hose-end valve does not have a bleed
port, a separate device must be used for
evacuation.
C. Purging using a Type 1 connection: L.P.
gas cylinder evacuation can be accomplished
during each purging by using a Type 1
connection. The Type 1 valve outlet has 1-
5/16" external ACME right-hand thread that will
accept this connection.
CAUTION:
cylinder, do not insert a POL plug into the
Example A
valve outlet. Insertion of this plug will prevent
the back-check from closing. Use ONLY the
provided cap and strap attached to the outlet.
Close the cylinder valve knob before returning
the cylinder to the customer.
For proper purging procedures in the USA,
refer to: Safety Bulletin NPGA # 133, "Purging
L.P. Gas Cylinders," and Safety Bulletin NPGA
#130, "Recommended Procedures for Filling
Cylinders."
DANGER:
beyond 80% full. If this information is not
followed exactly, a fire causing serious injury
or death may occur.
Example B
8
After purging or filling an L.P. gas
Do not fill an L.P. gas cylinder