7.2

Plastic hose is twisting

Fault description:
The swivel arm can no longer be extended. (mechanically
blocked)
Cause of fault:
The plastic hose has become so twisted that the swivel arm
is blocked.
Troubleshooting:
Remove the appliance, loosen the pipe clip and fit plastic hose
without twisting it.
142_58300000122107_ara_en_b.doc – 02.02.09
7.3

Too little air power

Complaint:
Extraction is too weak or the fumes go past the extraction arm.
Cause:
Units VL 051 and GB 031 have a free-blowing air power
of 350 m³/h. (See performance characteristic)
Additional pipelines reduce the power further. Flat ducts are
unsatisfactory as regards air flow and should not be used.
The intake area of the swivel arm is very small in comparison
with a hood. Depending on the position of the hob, not all fumes
are detected.
Rectification:
Check direction of rotation of the fan.
Check pipe installation. If pipelines are long or flat ducting is
used, the air power is reduced considerably.
Viewing the intake connection
from above, the fan impeller must
rotate in a clockwise direction.
Seite 15 von 16