Warning: Always wear eye protection. Operator of tool is responsible for following: accepted eye, face, respiratory, hearing and body protection.
Caution: Hand, wrist and arm injury may result from repetitive work, motion and overexposure to vibration.
• Keep hand and clothing away from working end of the air tool.
Operation: Be sure that any loose clothing, hair and all jewelry is properly restrained.
• Secure inlet bushing on air tool with a wrench before attempting to install the air fitting to avoid damaging housing assembly.
• Check tool RPM (speed) with tachometer with air pressure set at 90 PSIG while the tool is running. If tool is operating at a higher speed than the RPM marked on the tool
housing, or operating improperly, the tool must be serviced and corrected before use.
Caution: Tool RPM must never exceed abrasive/accessory RPM rating. Check accessory manufacturer for details on maximum operating speed or special mounting instructions.
• With power source disconnected from air tool, mount types 16, 17, 18, 18R and 19 Cone and plug wheels onto 3/8"-24 UNF-2A Spindle thread.
CONE or PLUG MOUNTING
Typical Mounting for Cone or Plug Wheels
• Inspect abrasive, spindle thread and spindle adapter for wear or damage.
• Blotters must cover at least the adapter surface as shown.
• A blotter (compressible washer) shall always be used between the
abrasive cone or plug surface and the adapter to ensure uniform
distribution of pressure.
• New blotters shall be used each time a wheel is mounted unless blotters
are affixed to the cone or plug by the manufacturer.
• Connect air tool to power source. Be careful NOT to depress throttle lever in the process.
Do not expose air tool to inlet pressure above 90 PSIG or (6.2 Bars).
Caution: After installing the accessory, the Extension Grinder must be started at a reduced speed to check for good balance. Gradually increase tool speed.
DO NOT USE if tool vibration is excessive. Correct cause, and retest to insure safe operation.
• Release the throttle lever in case of an interruption of the energy supply.
• Make sure that work area is uncluttered, and visitors are at a safe range from the tools and debris. Potentially explosive atmospheres can be caused by dust and
fumes resulting from sanding or grinding. Always use dust extraction or suppression systems which are suitable for the material being processed.
• Ensure that sparks and debris resulting from work does not create a hazard.
• Use a vise or clamping device to hold work piece firmly in place.
• To reduce operator fatigue use 53199 Collar to mount to suspension device.
• Do not apply excessive force on tool or apply "rough" treatment to it.
• Always work with a firm footing, posture and proper lighting.
Report to your supervisor any condition of the tool, accessories, or operation you consider unsafe.
Regulator
Filter
90 PSIG
(6.2 Bar)
• Dynabrade Air Power Tools are designed to
operate at 90 PSIG (6.2 Bar/620 kPa) maximum
air pressure at the tool inlet, when the tool is
running. Use recommended regulator to control
air pressure at each work station, if the supply
pressure is high.
• Ideally the air supply should be free from
moisture. To facilitate removing moisture
from air supply, the installation of a
refrigerated air dryer after the compressor
and the use of drain valves at each
tool station is recommended.
Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade
OPERATING INSTRUCTIONS
Spindle
Adapter
Driving Flange
with Flat Bearing Surface

Air System

Lubricator
Closed Loop Pipe System
(Sloped in the direction of air flow)
To Tool Station
Filter
Ball
Valve
Drain
Valve
Drain
Valve
Air Tool
90 PSIG MAX
2
Spindle is shorter than hole providing proper clearance.
Blotter
LUBRICATOR SETTING
Regulator
Lubricator
Air Hose
Coupler
(6.2 Bar )
Drain Valve
Cone or Plug
1 DROP/MIN.
20 SCFM
Air Flow
Refrigerated
Air Dryer
Ball
Valve
Air Flow
Air Compressor
and Receiver