{카테고리_이름} Dynabrade 61200에 대한 안전, 작동 및 유지보수 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Dynabrade 61200 12 페이지. Electric drum vacuum
Decrease in Vacuum Performance
•
Make sure the vacuum head power cord is undamaged and plugged into correct power supply.
(If machine still does not start, contact a certified electrician for review and repair).
•
Disconnect power supply of DrumVac and check condition of HEPA filter and ensure all vacuum hoses and inlets are free of debris. If damaged, replace with
Dynabrade parts.
•
Clean the filter thoroughly and as often as necessary. The filter used inside is water-resistant and washable. To prevent damage, do not use high pressure or
solvent to wash the filter.
•
If the filter (P/N 80459) should become damaged or badly clogged and cannot be cleaned, replaced with a new one.
•
This vacuum is equipped with an Electronic Thermal Protection Device. If the vacuum stops and the red indicator light appears ON, the unit has shut down as
a result of increased temperature. Once the unit has regained a temperature that is allowable for operation the vacuum will resume operation.
This appliance must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to
reduce the risk of electric shock.
This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug.
The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician
or service person if you are in doubt as to whether the outlet is properly grounded.
Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adaptor should be used with this appliance.
This appliance is for use on a nominal 120-Volt circuit and a grounding attachment plug that looks like the plug illustrated in sketch (A)
A
TROUBLESHOOTING
GROUNDING INSTRUCTIONS
FOR COMMERCIAL USE
DRY VACUUM CLEANERS
INDOOR USE ONLY
5