Cabinet Installation
Before installation, ensure the domestic electrical mains supply to which the
cabinet is to be connected is turned off. Before drilling, ensure that there are
It is recommended that this product is installed by two people.
This product can only be recessed fitted into a wall. Before installing ensure
you take note of measurements of the recessed area and the side fixing
points inside the cabinet carcass (See fig. 2 & 5).
You may need to remove the door / doors to make it easier to fit, see Door
Removal page 4. Do not fit the shelves until product is installed correctly.
If a separate trim set has been purchased this will need to be fitted onto the
cabinet, prior to full installation. Please see trim set installation guide on
1.
Measure the dimensions of the cabinet carcass (excluding the front aluminium
fascia trim).
2. Using these dimensions, take a soft pencil and mark the outline for the
required aperture in the wall. Take great care to mark this accurately, straight
and level.
3. Using an appropriate tool, cut or channel out the aperture in the wall where
the cabinet will fit, see Fig. 2.
4. If it is necessary, install supporting baton(s) or noggin(s) around the recessed
area, see Fig. 3, to which the cabinet can be secured. These supports must be
completely vertical and parallel to the cabinet to prevent the cabinet twisting
when fitted.
5. Connect the cabinet to the domestic mains supply according to the wiring
diagram, see page 3, and position the cabinet into the wall aperture, see Fig.
4.
6. Using a suitable screwdriver or drill, secure the cabinet into the wall aperture,
via the two holes located on the internal edge of the cabinet using the
supplied screws (two on each side) see Fig. 5.
7. Insert the metal shelf supports in desired position. Install each glass shelf into
shelf supports and tighten the plastic grub screw on the underside. This will
securely clamp the shelf into position, see Fig.6.
8. If necessary, hinges can be adjusted to reposition the door(s) see Door
Adjustment on page 4.
9. Switch mains supply back on.
6
no hidden cables or pipes in the wall.
page 7.