HiB Proton 피팅 지침 - 페이지 3

{카테고리_이름} HiB Proton에 대한 피팅 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. HiB Proton 4 페이지. Cabinets

the base of the cabinet with the supplied
screw and screw cap.
11. Once fully secure, close the internal
panel(s) using the screws removed at stage
6.
12. Fit shelves in desired positions using metal
shelf supports.
13. If necessary, the hinges can be adjusted in
order to reposition the door(s) (Fig. D).
14. Attach the LED light fitting on the top of
the cabinet using the pre-drilled holes and
screws provided. Push the male and female
electrical connector together until they
'click' . (Fig. E).
15. Switch the mains supply back on.
Door Adjustment (Fig D)
Attachment Light Fitting (Fig E)
Operating Instructions
To turn illumination on or off, wave hand under
the sensor switch located underneath the
cabinet.
How to Isolate the sensor so you can
switch ON & OFF with a mains switch.
How the cabinet is wired.
live
earth
neutral
Shaver socket/transformer
Sensor switch controller
LED driver
How to isolate the sensor.
live
earth
neutral
Shaver socket/transformer
Sensor switch controller
LED driver
Rewire the cabinet as shown in the diagram
above. HiB recommends that all electrical
bathroom products should only be fitted by a
suitably qualified, Part P registered electrician.
For further assistance on isolating the sensor
please contact us.
Tel:
020 8441 0352
Email:
hib.co.uk