This product is suitable for installation in zones:
&
2
Outside Zone
All installations must comply with guidelines which are based on a zonal
concept. The diagram above illustrates this concept and must be followed
to ensure the safe installation of electrical appliances in the bathroom.
These regulations apply to domestic installations only. Installations must be
made in accordance with the current IEE wiring regulations and relevant
building regulations. HiB recommends that all electrical bathroom
products should only be fitted by a suitably qualified, Part P registered
electrician.
Please Note these products must be installed with a
minimum distance
of 150mm between the infra-red sensor switch and any
surface or object
to ensure correct operation of the sensor.
Installation
1. Position the mirror in a suitable location (according to the zonal
diagram below-left), ensuring that the domestic electrical mains
supply is within reach of the electrical entry point of the product.
2. Carefully mark the position of the mirror using a soft pencil.
3. Remove the mirror and mark the mounting points according to the
diagram on the left. Please ensure that all marked mounting
points accurately match up with the fixing points on the
mirror.
4. Before drilling, ensure there are no hidden cables or pipes
behind the mounting points. Using a masonry drill, drill holes
in the marked positions to a suitable depth. If drilling through tile,
use a ceramic drill bit.
5. Insert wall plugs level with the surface of the wall. If fitting to a
tiled surface, wall plugs should be inserted below the tile surface
to avoid cracking. NB. For plasterboard walls, specialist fixings
should be purchased, available from any DIY or hardware store.
6. Screw hook screws into wall plugs.
7. Ensure the domestic electrical mains supply to which the mirror is
being connected is turned off. Connect the domestic mains supply
to the terminal box according to the wiring diagram (Fig. B).
8. Hang the mirror in position.
T:
+44 (0)20 8441 0352
F:
+44 (0)20 8441 0219
Building 3, North London Business Park, Oakleigh Road South, New Southgate, London. N11 1GN
©HiB Copyright: No part of this document may be reprinted or duplicated without HiB consent. All sizes and measurements are approximate, but we do try and make sure they are as accurate as possible. In the
interest of continuous product development, HiB reserves the right to alter specifications as necessary. E & OE.
Illuminated Mirrors
Maxi
Art No. 73106100
Zenith
Art No. 73105500
Thank you for purchasing this HiB product.
Please read through these instructions carefully and refer back to them
during installation to ensure that your product is fitted safely and that it
retains its high quality finish.
Please retain this leaflet for future reference.
Before installation, ensure the domestic electrical mains supply to
which the mirror is to be connected is turned off. Before drilling,
ensure that there are no hidden cables or pipes in the wall.
(Fig. 1)
Mounting Points Diagram (Fig. A)
Min. 150mm
Wiring Diagram (Fig. B)
Earth is Green and Yellow
LUMINAIRE
E:
hib.co.uk
REAR VIEW
mounting points
electrical input
REAR VIEW
mounting points
electrical input
Wiring Diagram
Live is Brown
live
earth
Neutral is Blue
neutral
FI#01 007 R151124
to mains
to mains
Live supply can be Red or Brown
Earth supply is Green and Yellow
Neutral supply can be Blue or Black
MAINS SUPPLY
Ver No.
1.0 Jan 2016