Dynacord Echocord Super 76 운영 매뉴얼 - 페이지 10

{카테고리_이름} Dynacord Echocord Super 76에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dynacord Echocord Super 76 13 페이지.
Dynacord Echocord Super 76에 대해서도 마찬가지입니다: 사용 설명서 (16 페이지)

Dynacord Echocord Super 76 운영 매뉴얼
When the ,ECHOCORD-SUPER" is combined with the DYNACORD amplifiers
EMINENT, KING, REX, etc. there is the possibility of providing the microphones and
instruments which
are connected to the amplifier, with reverberation or echo effect.
After having made all settings on the ECHOCORD-SUPER 76 and after having set
the volume control, tone control, and totalizing volume control on the amplifier to the
desired room volume, switch on the reverberation switches on the amplifier. The
volume for reverberation and/or echo is set on the ,Reverberation level control" (25)
by means of a small screw driver.
Turning clockwise increases, turning counterclockwise decreases echo/reverberation.
Normally this control has to be set only once and can then remain in this position.
If a disturbing hum should occur when connecting the units, a defective or impro-
perly connected- shielded cable ts often the cause. Moreover, such hum may also be
caused by a larger power transformer of a nearby amplifier. In this case place the
units at such a distance from each other (if necessary turn slightly) that a mutual
interference is eliminated.
Examples for interconnecting the ECHOCORD-SUPER 76
new DYNACORD amplifiers
Eminent (/il, Basskeng 1, Gigunt etc.
output socket
fa
other amplifiers
@