HiB Breeze 31100 매뉴얼 - 페이지 3

{카테고리_이름} HiB Breeze 31100에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. HiB Breeze 31100 4 페이지. Wall mounted fans

HiB Breeze 31100 매뉴얼
1)
Ensure the domestic electrical mains supply
to which the fan is being connected is
turned off. This product is designed to be
connected to an on/off switch outside the
bathroom, or to a ceiling mounted pull cord
switch.
2) Hush Only: Remove the front panel and
protective cover (4). Pass the power
wire through the hole in the rubber plug
(beneath protective cover) at the fan casing
flange.
3) Breeze Only: Remove the protective grille.
Lead the power supply cords through the
hole (5) which should be cut before in the
plastic casing.
4) Make the electric connections according to
the relevant wiring diagram below.
Hush
LT (Switch Live)
L
N
Breeze
L
LT (Switch Live)
N
5) Fix the fan to the wall using 4 screws.
6) Replace the cover and protective grille.
Technical Information
Hush
Power input: 220-240 V, 50 Hz
Maximum ventilation volume: 97 m
Power consumption: 7.5W
Dimensions: W158 x H158 x D107mm
Breeze
Power input: 220-240 V, 50 Hz
Maximum ventilation volume: 88 m
Power consumption: 14W
Dimensions: W152 x H152 x D126mm
Operating Instructions
1) For Art Nos. 33100/31700/31500/3280
0/31300/31100
Fan with timer option switches on as control
voltage is supplied to LT terminal. After
voltage is off, the fan continues operating
within the set time period T, adjustable
between 2 and 30 min. The time is regulated
by turning the potentiometer T clockwise to
increase and anticlockwise to decrease the
running-out time.
2) For Art Nos. 33200/31800/31600/3290
0/31400/31200
Fan with timer and humidity sensor switches
on as control voltage is supplied to LT
terminal or when humidity level adjustable
between 60% and 90% is exceeded. After
voltage is off or humidity level H decreases
the fan continues operating within the set
time period adjustable between 2 and
30 min. Time T and humidity H values
are regulated by turning the appropriate
potentiometers T and H clockwise to
increase and anticlockwise to decrease
the running-out time and humidity level
respectively. To set the maximum humidity
level set the potentiometer in H max (90%)
position.
/hr (±5%)
3
Maintenance
Fan maintenance is to be performed only after
the fan is disconnected from the mains power
/hr (±5%)
3
supply. Maintenance means periodic clearing
of the surfaces from dust and dirt.
3
hib.co.uk