HP- 150 / 200
STEP
STEP
MOUNTING THE ELECTROMAGNET
4
4
Mount new electromagnet in the unit.
Fix frame stay temporarily.
(Do not tighten screw of frame stay and keep
them rather loose.)
Tighten up hexagonal nuts with nut driver.
Fasten screws of frame stay.
STEP
STEP
5
5
Install the SP switch to the frame with the screws.
●Be careful of the direction of switch lever. (Refer to the
pictures)
STEP
STEP
6
6
Insert the wire into the silicon tube, and tie up in a
bundle.
Strip the coating off each wire.
(5-7mm from the end)
Connect the wires to the terminals.
Solder the wires to the terminals.
The wire requires a soldered connection.
STEP
STEP
7
7
This completes the electromagnet replacement
procedure.
8