HIBLOW hp-150 매뉴얼 - 페이지 3
{카테고리_이름} HIBLOW hp-150에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. HIBLOW hp-150 8 페이지. Air pumps
HIBLOW hp-150에 대해서도 마찬가지입니다: 사용 설명서 (13 페이지), 사용 설명서 (17 페이지)
HP- 150 / 200
STEP
STEP
4
4
Remove 2 U-lock nuts from one side holding the
diaphragm mounting block to the rod.
●Use the nut driver to loosen (or tighten) the U-lock nut.
STEP
STEP
5
5
Remove one of the diaphragm mounting blocks
from the actuating rod and pull out the other
diaphragm mounting block with the rod. After
that, separate the diaphragm mounting block and
the rod.
●When pulling out the rod, be sure not to catch the rod
projection on the lever of the SP switch.
●If the pump stops automatically, the safety pin must be broken to prevent any
further damage to the pump. Be sure all broken pieces are removed from the unit.
(See Step 14)
STEP
STEP
REPLACING THE DIAPHRAGM
6
6
In case of replacing the whole diaphragm
mounting block, move straight to
Remove the diaphragm ring from the diaphragm,
and then, detach the diaphragm from the
diaphragm base.
STEP
STEP
7
7
Fit a new diaphragm and diaphragm ring in the
diaphragm base.
●Be sure not to leave a gap between them.
REPLACING THE CHAMBER BLOCK
STEP 11
.
3