HIBLOW hp-150 사용 설명서 - 페이지 11

{카테고리_이름} HIBLOW hp-150에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. HIBLOW hp-150 17 페이지. Air pumps
HIBLOW hp-150에 대해서도 마찬가지입니다: 사용 설명서 (13 페이지), 매뉴얼 (8 페이지)

HIBLOW hp-150 사용 설명서
Fig. 17
Casing A
(10) After the valves have been inserted into the casing A, cut off their respective pulling ends using
scissors or nippers. Secure casing B and valve chamber packing to casing A by the five screws.
This completes the valve replacement procedure, and use this assembly as a new casing block.
Fig. 19
Cut section
• When replacing the diaphragms, be sure to change the valves with new ones, too.
• When reinstalling the valves, take care to make sure that they are correctly fit in the exhaust and
intake sides. Wrong orientation may result not only in performance decreasing but in a failure of
the pump.
• Tighten each of five screws gradually and uniformly till they are firmly fastened.
If they are not tightened uniformly, it may cause leakage of air or failure of pump.
Valve
Cut section
CAUTION
Fig. 18
Exhaust side
Fig. 20
Intake side
(Fig. 19 and 20)
11